TEST: Surviving An Inspection
|
1. Dose calibrators must be tested periodically for accuracy, constancy, linearity, and geometry. The required frequency, respectively, is...Daily, weekly, monthly, quarterly Annually,
daily, quarterly, at installation Annually, quarterly, daily, at installation Quarterly, annually, at installation, daily |
|
2. Regular room monitoring by Nuclear Medicine Technologists is mandatory. What is the required frequency of performance of this monitoring?GM Counter daily, wipe test daily GM Counter daily, wipe test weekly GM Counter weekly, wipe
test daily GM Counter weekly, wipe
test weekly |
|
3. Regular hand monitoring by Nuclear Medicine Technologists is mandatory. What is the required frequency of performance of this monitoring?After each study Before lunch and before leaving at end of the day Daily Weekly |
|
4. Which one of the following statements regarding licensure for use of radioisotopes is true?The director of Nuclear Medicine is licensed The director of Radiology is licensed Each individual user of isotopes is licensed The
institution is licensed |
|
5. Treadmill monitoring by Nuclear Medicine Technologists is mandatory. What is the required frequency of performance of this monitoring?After each study Before
lunch and before leaving at end of the day Daily Weekly |
|
6. Radiation readings are received on a monthly basis from the film badge monitoring service. By law, how frequently must your department chairman notify you of your radiation exposure levels? Weekly Monthly Annually Notification is not mandatory |
|
7. You assisted in the administration of a 10 mCi therapy dose of I-131 NaI. Which one of the following is required?You must have your thyroid monitored 24 hours after dose administration The RSO must collect a urine and blood sample from everyone present You must take 200 mg of potassium iodide p.o. prior to dose administration None of the above is required |
|
8. The institution’s ALARA Program and Radiation Safety Program must be reviewed...Monthly Semi-Annually Annually Every
3 Years |
|
9. Leak testing on all sealed sources (e.g., Co-57 floods and spot markers, dose calibrator check sources) must be done on a periodic basis. The required frequency for checking sealed sources is...Monthly Quarterly Semi-Annually Annually |
|
10. The only isotope commonly used in Nuclear Medicine which is not found on a wipe test isGa-67 In-111 I-123 Xe-133 |
|